Appendix 1 of the Gas Safety Legislation states that flue joints should be available to inspect -

Our cascade flue installation in apartments is the only flue system that requires one single inspection point in each apartment

 

Cascade Flue Systems

Solutions for Apartment Buildings

The vertical cascade flue system from Evinox prevents multiple flue penetrations through roofs or walls by allowing up to 11 boilers on 11 levels to share a common 110mm flue riser, making it ideal for modern buildings with glass facades.

The Evinox range of wall hung, condensing system and combination boilers are designed for use with our unique cascade flue system for apartment installations. An inbuilt non return valve on the boiler fan, allows for direct connection to the cascade system.

With the Gas Safe Register & Building Control reinforcing the rules of Appendix 1 of the Gas Safety Legislation, which states that flue joints should be available to inspect. Our cascade flue installation in apartments is the only flue system that requires one single inspection point in each apartment.

This is due to the single flue joint on the branch connection of each dwelling. Utilising a riser shaft with an internal measurement of 200mm x 200mm, the flue system uses less valuable space in the building than 11 individual flues, with no pluming problems through the façade.

Contact Evinox today on 01372 722277 for further information or to arrange for one of our Technical Sales Specialists to visit. 

2009 awards winner logoIndustrial/Commercial and Domestic Product of the Year